O-N-H Analyzers – Dev https://dev.additiveplus.com Wed, 21 Aug 2024 12:25:40 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.5 https://dev.additiveplus.com/wp-content/uploads/cropped-AdditivePlus-Logo-Vertical-Dark-32x32.png O-N-H Analyzers – Dev https://dev.additiveplus.com 32 32 shopengine_activated_templates a:1:{s:6:"single";a:1:{s:4:"lang";a:1:{s:2:"en";a:1:{i:7;a:3:{s:11:"template_id";i:53939;s:6:"status";b:1;s:11:"category_id";s:3:"912";}}}}} H‑500 https://dev.additiveplus.com/product/h%e2%80%91500/ Wed, 21 Aug 2024 12:07:04 +0000 https://dev.additiveplus.com/?post_type=product&p=52931 H-500 is designed for the rapid and accurate determination of hydrogen in these material

The post H‑500 appeared first on Dev.

]]>

PRODUCT ADVANTAGES

APPLICATION EXAMPLES

Alloys, copper, steel

FUNCTIONAL PRINCIPLE

Operating the H-500 is simple and safe. After weighing the sample on the interfaced electronic, the weight is transferred to the connected PC. It is also possible to enter the weight manually via the H-500 software.

 

The sample is placed into the cold zone of the horizontally positioned furnace.After starting the analysis, the furnace is rotated upwards for the sample to fall into the hot zone. By adding nitrogen as carrier gas hydrogen diffuses out and is carried into a sensitive thermal conductivity cell.

 

The typical analysis time is about 3 to 15 minutes. Detector signals and instrument parameters are displayed during analysis. Evaluation of the signals and display of the results are done automatically; the data can be transferred to a laboratory information management system (LIMS). The H-500 requires minimum maintenance. The particle filters and chemicals which need to be maintained are easily accessible.

The post H‑500 appeared first on Dev.

]]>
ELEMENTRAC ON‑p 2 https://dev.additiveplus.com/product/elementrac-on%e2%80%91p-2/ Wed, 21 Aug 2024 11:49:16 +0000 https://dev.additiveplus.com/?post_type=product&p=52922 ELEMENTRAC ON-p 2 is a elemental analyzer for measurement of oxygen and nitrogen concentrations

The post ELEMENTRAC ON‑p 2 appeared first on Dev.

]]>

OXYGEN / NITROGEN ANALYZER ELEMENTRAC ON-P 2

CONFIGURATIONS

The ELEMENTRAC ON-p 2 elemental analyzer is available as a single-element analyzer for oxygen or nitrogen only, or in a multi-element configuration for measuring ON. Whereas oxygen is determined as CO2 in up to two infrared cells, nitrogen is detected in its elemental form in a thermal conductivity cell.

INTEGRATED STANDARD SOLUTIONS

The chemicals and filters required for operation of the elemental analyzer are arranged conveniently on the front panel and can be concealed behind a removable door during routine operation. This arrangement significantly reduces the time required for maintenance and increases user-friendliness. In addition, innovative details considerably improve the reproducibility of measurements.

Options

In addition to the integrated solutions of the ELEMENTRAC ON-p 2, further options are available to increase efficiency and extend the application range of your elemental analysis.

Software

TYPICAL SAMPLE MATERIALS

Alloys, aluminum, ashes, carbides, cast iron, ceramics, copper, ferroalloys, iron, metals, ores, refractory metals, silicon, steel

FUNCTIONAL PRINCIPLE

The measuring principle of the ELEMENTRAC ON-p 2 elemental analyzer allows for a wide measuring range. To analyze the sample, it is weighed and placed on the sample port. Flushing with carrier gas prevents atmospheric gas (oxygen and nitrogen) from getting into the furnace.

 

The graphite crucible is outgassed in the impulse furnace of the analyzer to reduce possible contaminations (e.g. residual hydrogen). After a stabilization phase the sample is dropped into the crucible and melts. Carbon monoxide is produced by the reaction of carbon in the graphite crucible and oxygen of the material. Nitrogen and hydrogen are released in its elemental form. The carrier gas (helium) and sample gasses pass through a filter before entering a copper oxide catalyst which converts the CO to CO2.

 

The CO2 is then measured by infrared cells to determine the oxygen content. CO2 and water are removed chemically and the nitrogen content is measured in the thermal conductivity cell. As an option the less expensive Argon can be used in the elemental analyzer to determinate the oxygen and nitrogen content.

The post ELEMENTRAC ON‑p 2 appeared first on Dev.

]]>
ELEMENTRAC OH‑p 2 https://dev.additiveplus.com/product/elementrac-oh%e2%80%91p-2/ Wed, 21 Aug 2024 11:14:29 +0000 https://dev.additiveplus.com/?post_type=product&p=52909 ELEMENTRAC OH-p 2 is a elemental analyzer for measurement of oxygen and hydrogen concentrations

The post ELEMENTRAC OH‑p 2 appeared first on Dev.

]]>

OXYGEN / HYDROGEN ANALYZER ELEMENTRAC OH-P 2

CONFIGURATIONS

The ELEMENTRAC OH-p 2 is available as a single-element analyzer for oxygen or hydrogen only, or in a multi-element configuration for measuring OH. Whereas oxygen is determined as CO2 in up to two infrared cells, nitrogen and hydrogen are detected in their elemental form in a thermal conductivity cell.

INTEGRATED STANDARD SOLUTIONS

The chemicals and filters required for the operation of the ELEMENTRAC OH-p 2 elemental analyzer are arranged conveniently on the front panel and can be concealed behind a removable door during routine operation. This arrangement significantly reduces the time required for maintenance and increases user-friendliness. In addition, innovative details considerably improve the reproducibility of measurements.

Options

In addition to the integrated solutions of the ELEMENTRAC OH-p 2 elemental analyzer, further options are available to increase efficiency and extend the application range.

Software

TYPICAL SAMPLE MATERIALS

Alloys, aluminum, ashes, carbides, cast iron, ceramics, copper, ferroalloys, iron, metals, ores, refractory metals, silicon, steel

FUNCTIONAL PRINCIPLE

The measuring principle of the ELEMENTRAC OH-p 2 elemental analyzer allows for a wide measuring range. To analyze the sample, it is weighed and placed on the sample port. Flushing with carrier gas prevents atmospheric gas (oxygen) from getting into the furnace.

 

The graphite crucible is outgassed in the impulse furnace of the analyzer to reduce possible contaminations (e.g. residual hydrogen). After a stabilization phase the sample is dropped into the crucible and melts. Carbon monoxide is produced by the reaction of carbon in the graphite crucible and oxygen of the material. Hydrogen is released in its elemental form. The carrier gas (nitrogen) and sample gasses pass through a filter before entering the Schuetze reagent which converts the CO to CO2, whereas hydrogen remains in its elemental form.

 

The CO2 is measured by the infrared cells and removed chemically. Afterwards the hydrogen content is determined in the thermal conductivity cell.

The post ELEMENTRAC OH‑p 2 appeared first on Dev.

]]>
ELEMENTRAC ONH‑p 2 https://dev.additiveplus.com/product/elementrac-onh%e2%80%91p-2/ Wed, 21 Aug 2024 09:53:13 +0000 https://dev.additiveplus.com/?post_type=product&p=52892 ELEMENTRAC ONH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen

The post ELEMENTRAC ONH‑p 2 appeared first on Dev.

]]>

OXYGEN / NITROGEN / HYDROGEN ANALYZER ELEMENTRAC ONH-P 2

CONFIGURATIONS

The ELEMENTRAC ONH-p 2 elemental analyzer is available as a single-element analyzer for oxygen, nitrogen or hydrogen only, or in a multi-element configuration for measuring ON, OH, NH, or ONH. Whereas oxygen is determined as CO2 in up to two infrared cells, nitrogen and hydrogen are detected in their elemental form in a thermal conductivity cell. The ELEMENTRAC ONH-p 2 elemental analyzer uses an ON mode with helium carrier gas (optionally argon) and an OH mode with nitrogen carrier gas to take advantage of the sensitive thermal conductivity cell.

INTEGRATED STANDARD SOLUTIONS

The chemicals and filters required for the operation of the ELEMENTRAC ONH-p 2 elemental analyzer are arranged conveniently on the front panel and can be concealed behind a removable door during routine operation. This arrangement significantly reduces the time required for maintenance and increases user-friendliness. In addition, innovative details considerably improve the reproducibility of measurements.

Options

In addition to the integrated solutions of the ELEMENTRAC ONH-p 2, further options are available to increase efficiency and extend the application range of your elemental analysis.

Software

TYPICAL SAMPLE MATERIALS

Alloys, aluminum, ashes, carbides, cast iron, ceramics, copper, ferroalloys, iron, metals, ores, refractory metals, silicon, steel

FUNCTIONAL PRINCIPLE

The measuring principle of the ELEMENTRAC ONH-p 2 elemental analyzer allows for a wide measuring range. To analyze the sample, it is weighed and placed on the sample port. Flushing with carrier gas prevents atmospheric gas (oxygen and nitrogen) from getting into the furnace.
The graphite crucible is outgassed in the impulse furnace of the analyzer to reduce possible contaminations (e.g. residual hydrogen). After a stabilization phase the sample is dropped into the crucible and melts. Carbon monoxide is produced by the reaction of carbon in the graphite crucible and oxygen of the sample. Nitrogen and hydrogen are released in its elemental form. The carrier gas (helium) and sample gasses pass through a filter before entering a copper oxide catalyst which converts the CO to CO2.

 


The CO2 is measured by the infrared cells to determine the oxygen content. CO2 and water are removed chemically and the nitrogen content is measured in the thermal conductivity cell. In the case of hydrogen analysis, nitrogen carrier as well as sample gas pass through a Schuetze reagent instead of a copper oxide catalyst. As an option the less expensive Argon can be used to determinate the oxygen and nitrogen content during analysis.

The post ELEMENTRAC ONH‑p 2 appeared first on Dev.

]]>